All Manuals Close Window

Service Lubrication


Grease

IMPORTANT: Avoid damage! Use recommended John Deere greases to avoid component failure and premature wear.

The recommended John Deere greases are effective within an average air temperature range of -29 to 135 degrees C (-20 to 275 degrees F).

If operating outside that temperature range, contact your Servicing dealer for a special-use grease.


The following greases are preferred:

• John Deere Multi-Purpose SD Polyurea Grease

• John Deere Multi-Purpose HD Lithium Complex Grease

If not using any of the preferred greases, be sure to use a general all-purpose grease with an NLGI grade No.2 rating.

Wet or high speed conditions may require use of a special-use grease. Contact your Servicing dealer for information.

The following lubricant is preferred:

• SUPER LUBE® lubricant.1

Lubricating Machine Grease Fittings

Extremely Wet and Muddy Conditions - Lubricate machine grease fittings every 10 hours of operation or on a daily basis.
All Other Conditions - Lubricate machine grease fittings every 50 hours of operation.

MX22562

A - Tie Rod Ends

B - Axle Pivot Pin

Lubricating Hydraulic Selective Control Valve (SCV) Linkage


MX35665

Picture Note: Shown with access cover removed.

• Lubricate SCV linkage (A) and SCV lock lever (B) with SUPER LUBE lubricant.

Lubricating Hood Latch


MX35730

• Lubricate hood latch (A) with SUPER LUBE lubricant.

Lubricating 3-Point Hitch


MX35591

• Lubricate ball joints (A) with SUPER LUBE lubricant.

1

SUPER LUBE is a registered trademark of Synco Chemical Corp.